Hantek 1008C USB 8CH 2.4MSa/s Automotive Diagnostic Oscilloscope DAQ Programmable Generator Vehicle Testing

Hantek 1008C USB 8CH 2.4MSa/s Automotive Diagnostic Oscilloscope DAQ Programmable Generator Vehicle Testing
  • First Diagnosis: Intake manifold vacuum & ignition, Petrol fumes adjusting valve vacuum & ignition, Idle exhaust ignition, Starting exhaust ignition. Ignition: primary and secondary.USB 2.0 interface plug and play, and no need extra power supply;
  • Sensor: Air Flow Meter, Camshaft, Crankshaft, Distributor, Lambda sensor, Throttle position. Bus Diagnosis: CAN bus data examine, CAN bus signal integrity, CAN bus LH long time acquisition, LIN bus.More than 20 types of automatic testing function, a similar interface with benchtop oscilloscope, easy to use;
  • Performer: Petrol/Diesel. Starter and charging circuits. Software support: Windows NT, Window 2000, Windows XP, VISTA, Windows 7, Windows 8.
  • 8 channels oscilloscope, 2.4MSa/s real time sampling rate. 12 bits vertical resolution, spectrum analysis function.
  • Programmable Generator: 8 channels programmable generator. Can analog signals of crankshaft, camshaft etc.

Specifications:
Input Impedance    Resistance: 1MΩ
Input Sensitivity    10mV/div to 5V/div
Resolution    12 bits
Horizontal System
Memory Depth    4K
Max. Input    400V (DC+AC Peak)
Real-Time Sampling Rate    2.4MSa/s
Time Base Range    1ns/div to 20000s/div(1-2-5sequences)
Time Base Precision    ±50ppm
Trigger System
Time Base Range    1ns/div to 20000s/div(1-2-5sequences)
Time Base Precision    ±50ppm
Trigger Source    CH1, CH2, CH3, CH4, CH5, CH6, CH7, CH8
Trigger Mode    Edge
X-Y Mode
X-Axis Input    CH1
Y-Axis Input    CH2
Cursors and Measurement
Voltage Measurement    Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase,Vavg, Vrms, Vcrms, Preshoot, Overshoot
Time Measurement    
Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle
Cursors Measurement    Horizontal ,Vertical, Track, Auto Measure Modes
Waveform Signal Process    +,- , x,÷, FFT, Invert
Voltage Range    10mV to 5V/div @ x 1 probe
100mV to 50V/div @ x 10 probe
10V to 5000V/div @ x 1000 probe
100V to 50000V/div @ x 10000 probe
200mV to 100V/div @ 20:1
Current Range    100mA to50.0A/div @ CC65(20A)
1000mA to500.0A/div @ CC65(65A)
1A to100.0A/div @ CC650(60A)
1A to200.0A/div @CC1100(100A)
10A to2000.0A/div @CC1100(1100A)

Package List:
1 * 1008C DAQ oscilloscope
4 * Crocodile probes/cable
1 * secondary ignition probe
4 * BNC Connectors
1 * USB Cable
1 * CD

Lowest Price: £79.99